Kaelus iVA - Cable & Antenna Analyser » Castle Microwave

Kaelus iVA - Cable & Antenna Analyser

Kaelus iVA - Cable & Antenna Analyser

VSWR, Return Loss Measurement & Distance to Fault

The iVA Series Cable & Antenna Analyser is an exciting new product from Kaelus that enables users to accurately measure VSWR/return loss and the location of the VSWR/return loss faults in their RF infrastructure. The wireless connectivity allows unprecedented measurement flexibility and opens up new & important possibilities in sweep testing and multi-port testing.

The iVA is a rugged battery operated module that can be remotely controlled with any Bluetooth enabled tablet, smart phone, laptop computer or any of our iPA Series Portable Passive Intermodulation analysers.

iVA Product Features

  • Reinventing site certification sweep testing, dramatically reducing test time on site
  • Directly measure insertion loss and isolation when using multiple iVAs. Measure calculated insertion loss with a single iVA and an RF short
  • Accurately measure swept VSWR/return loss and Distance-to-Fault (DTF) in RF path
  • Can be used in conjunction with an iPA Series PIM Analyser to directly measure insertion loss and isolation
  • Connect directly to the device under test; eliminates the need for a phase stable cable in most cases a faster, simpler and more efficient workflow
  • With the Kaelus iPA controlling the iVA, your RL data can be combined with your PIM data into a single report. Reports are combined and completed on-site with no post-processing required
  • Uses the Kaelus customer-proven iPA reporting workflow & tagging features to facilitate a faster, simpler and more efficient workflow 
  • Simple to operate, highly intuitive software user interface with the unique ability to generate and complete the test report on site)
  • Geotag each test point, insert a Google Maps® snapshot directly into the report
  • Smart high power input protection when used with a Kaelus iPA

IVA Flyer

TECHNICAL SPECIFICATION

iVA Analysis Mode - Return Loss

iVA Analysis Modes 

Return Loss
VSWR
Cable Loss1
Distance-to-Fault (DTF)

Frequency Range

690 - 2700 MHz

Minimum Frequency Increment

1 kHz

Sweep Speed

4 ms per frequency point

Number of Measurement Points

2 to 2001

RF Output Power

+5 dBm ± 3 dB

Return Loss Dynamic Range

0 – 40 dB

VSWR Dynamic Range

1 – 100

Cable Loss Dynamic Range1

0 – 20 dB

Return Loss Measurement Accuracy

Applies over the temperature range −10°C to +45°C, with less than 5°C deviation from calibration temperature.

            0 – 10 dB

± 0.3 dB

           10 – 20 dB

± 0.6 dB

           20 – 30 dB

± 1.5 dB

           30 – 40 dB

± 4.0 dB

Calibrated Directivity

43 dB (typ)

Interference Immunity

+10 dBm at 500 kHz offset from stimulus frequency

System Impedance

50 ohms

1. Cable loss can be measured either as a 1-port measurement, with the far end of the cable terminated in an open or short circuit, or directly measured for increased accuracy as a 2-port measurement using a second iVA

iVA Analysis Mode - N-Port Transmission1

iVA Analysis Modes

Transmission Loss
Isolation

Frequency Range 

690 - 2700 MHz

Minimum Frequency Increment

1 kHz

Sweep Speed 

10 ms per frequency point

Number of Measurement Points 

2 to 2001

RF Output Power

+5 dBm

Dynamic Range

90 dB

Transmission Loss Measurement Accuracy

 

                0 – 10 dB

± 1 dB

              10 – 60 dB

± 2 dB

              60 – 90 dB

± 3 dB

Interference Immunity

 

               0 – 60 dB

-5 dBm at 500 kHz offset from stimulus frequency

              60 – 100 dB

-25 dBm at 500 kHz offset from stimulus frequency

1. The iVA offers a novel multi-port S-parameter test capability using multiple iVAs. Up to 7 units can be connected simultaneously via Bluetooth, while up to 32 can be connected via USB. As an example, 6 iVAs could be used to perform measurements on a multi-port antenna. This configuration would cover all 36 transmission pathways (6x6), including the return loss at each port (6 measurements), and the transmission loss between every possible pair of ports (30 measurements). Return loss measurements made by the iVA contain both both magnitude and phase information, while transmission loss measurements are limited to magnitude only.

iVA Analysis Mode - Spectrum Monitor

iVA Analysis Modes

Amplitude vs. Frequency

Frequency Range

690 - 2700 MHz

Minimum Frequency Increment

1 kHz

Sweep Speed

2 ms per frequency point

Receiver Noise Figure 1

15 dB

Measurement Noise Floor

−115 dBm Typical

Measurement Range

+20 to −115 dBm

Measurement Accuracy

±3 dB

Maximum Input Power without Damage2

+23 dBm

Input IP3

+18 dBm

Resolution Bandwidth

20 kHz

Interference Immunity

 

          Preamp On

−25 dBm at 500 kHz offset from stimulus frequency

          Preamp Off

−5 dBm at 500 kHz offset from stimulus frequency

Return Loss at iVA Test Port

10 dB (min) / 15 dB (typ)

1 Preamp on.

2 Damage can occur at input levels above +23dBm.

Instrument Control

User interface

USB or Bluetooth supported user device with iVA Application Software installed

 

Supported Devices

iPA Portable PIM Analyser
Tablet computer (iOS & Android)
Smartphone (iOS & Android)
PC, Windows 7 & 8 running .NET verison 4 or later

 

Communications Interface to iVA

Bluetooth and USB 2.0

 

Bluetooth Antenna

Integrated into housing

 

Maximum Input on RF Port

 

 

          RF

+23dBm max

 

          DC

Voltage±30V

 

Electrical

 

 

DC Power Consumption

 

 

       Return Loss Mode

4.7W

 

       Transmission Mode

4.7W

 

       Spectrum Monitor Mode

3.7W

 

            Standby (Idle)

0.6W

 

Battery

Lithium-Ion 3.6V, 2350 mAh, 8.5Wh

 

Battery Charging Method

USB-compatible power source connected to USB port of iVA

 

Battery Operating Time

8 Hours at typical usage factor

 

Mechanical & Environmental

 

 

Dimensions

2.06 x 2.73 x 8.51in (52 x 69.5 x 216mm)

 

Weight

1.4 lbs (640 g)

 

RF Test Port Connector

Type N male, 50Ω

 

USB Connector

USB 2.0 Mini-B

 

Operating temperature range

-10°C to +45°C

 

Storage temperature range

-20°C to +60°C

 

Relative humidity

5% to 95% RH non-condensing

 

Altitude

15,000 ft (4600 m) max

 

Ingress protection (IP)

IP54 (operating)

 

Mechanical Shock

MIL-PRF-28800F Class 2, ETS 300 019-2-1, -2, -7

 

EMC

EN 61326-1:2013, EN 61326-2-1:2013, EN 55022:2010 “Class A”

 

 

EN 61000-4-2, 4-3, 4-4, 4-5, 4-6, 4-11

 

ORDERING INFORMATION

MODEL PART #          
DESCRIPTION - CONTENTS
iVA-0727A-NC
Cable & Antenna Analyser 690-2700 MHz

     - R18-0640

1’(30cm) USB Cable

     - R18-0832

10’ (3m) USB Cable

     - R29-4362

AC Wall Charger 5V 2A USB

iVA-0727A-HC
iVA Cable and Antenna Analyser with Hard Case

     - iVA-0727A-NC

Cable & Antenna Analyser 690-2700 MHz

     - iAK-0200A-00

Single unit Hard Case Kit

iVA-0727A-BK
iVA Cable & Antenna Analyser System with Basic Accessory Kit

    - iVA-0727A-NC     

Cable & Antenna Analyser 690-2700 MHz

     - iAK-0200A-01

Single unit Hard Case Kit w/ Adaptors

iVA-0727A-SK
iVA Cable & Antenna Analyser System with Standard Accessory Kit

     - iVA-0727A-NC

Cable & Antenna Analyser 690-2700 MHz

     - iAK-0200A-02

Single unit Hard Case Kit w/ Adaptors and Calibration Kit

iVA-0727A-PK
iVA Cable & Antenna Analyser System with Premium Accessory Kit

     - iVA-0727A-NC

Cable & Antenna Analyser 690-2700 MHz

     - iAK-0210A-02

Premium Hard Case Kit w/ Adaptors, Calibration Kit, Phase Stable Cable and Battery Bank

 

ACCESSORY KIT PART #
DESCRIPTION - CONTENTS
iAK-0200A-00

Single unit Hard Case Kit

iAK-0200A-01

Single unit Hard Case Kit w/ Adaptors

iAK-0200A-02

Single unit Hard Case Kit w/ Adaptors and N Type Female Calibration Kit

 

-03 N Type Male Calibration Kit, -04 DIN Female Calibration Kit
-05 DIN Male Calibration Kit

iAK-0210A-02

Premium Hard Case Kit w/ Adaptors, Calibration Kit, Phase Stable Cable and Battery Bank

 

-03 N Type Male Calibration Kit, -04 DIN Female Calibration Kit,
-05 DIN Male Calibration Kit

Brochure Download
Request More information